TE

Trigger Edge

TE


Command Group: Checkweigher

Access:

Network interfaces:

RW

CANopen

SDO2500sub02

MODbus

2402,2

TE - Trigger Edge ^ selects rising or falling edge trigger

PROFIbus

read 38,2 write 38,130


Synopsis:
CommandResponse
GetTEE:<Value>
SetTE <Value>OK (or ERR)
Valid forMin. valueMax. value
141.181 0 1
141.184 0 1
141.185 0 1
141.186 0 1
142.181 0 1
142.184 0 1
142.185 0 1
142.186 0 1
143.181 0 1
143.184 0 1
143.185 0 1
151.181 0 1
151.184 0 1
151.186 0 1
162.181 0 1
179.181 0 1
64.181 0 1
68.181 0 1
72.181 0 1
78.183 0 1
88.183 0 1



TE This command selects rising or falling slope trigger. TE = 0 select falling slope and TE = 1 select rising slope. Factory default setting: 0 (falling slope).
Note that TE only works on WCN122 when an input has been assigned as Trigger input.

See also AIn