SC

Start Cycle

SC


Command Group: Filling

Access:

Network interfaces:

W

CANopen

SDO2005sub01

MODbus

2065,1,1

SC - Starts the Filling program.

PROFIbus

write 34,0


Synopsis:
CommandResponse
SetSCOK (or ERR)
Valid forMin. valueMax. value
141.184    
142.184    
143.184    
64.184    
72.184    
78.184    
88.184    



SC Issuing the SC command (which has no parameters), will start the filling cycle, i.e. the ‘Dose program running’ status bit will be set and the program will wait for a trigger pulse on input 0. If the load cell zero check function is not required, set PD3 (zero check time) to "0". The system then waits for a trigger pulse on input 1.

If the unit is a LDM88 - a TR command can be used instead of input 1.

See also AC, DI, DT, GD, TR.
PD1, PD2, PD3, PD4, PD5, PD6, PD7, PD8, PD9, PD10, PD11, PD12, PD13, PD14, PD15, PD16, PD17, PD18, PD19, PD20, PD21.