PD4

Filling weight

PD4


Command Group: Filling

Access:

Network interfaces:

RW

CANopen

MODbus

PD4 - Filling weight. Range: 0..99999

PROFIbus


Synopsis:
CommandResponse
GetPD4P4:<Value>
SetPD4 <Value>OK (or ERR)
Valid forMin. valueMax. value
72.184 0 99999



PD4 This is the target filling weight (in increments) which the filling algorithm tries to reach.
The filling stops when the Weight reaches PD4 - Inflight value (PD10)/100.

See also PD10, and PD2.