PD20

Tare interval

PD20


Command Group: Filling

Access:

Network interfaces:

RW

CANopen

SDO2200sub14

MODbus

2326,2

PD20 - Set amount of cycles to pass before next tare

PROFIbus

read 6,20 write 6,148


Synopsis:
CommandResponse
GetPD20P20:<Value>
SetPD20 <Value>OK (or ERR)
Valid forMin. valueMax. value
141.184 0 65535
142.184 0 65535
143.184 0 65535
151.184 0 65535
64.184 0 65535
88.184 0 65535



PD20 In some cases where the object being filled is not a new bottle, but say a box that is being emptied after each fill, the tare function is not necessary in every filling cycle. When parameter 20 is 0 (zero) taring only takes place in the very first filling cycle. When parameter 20 is 1 (one, default) the taring takes place in every filling cycle. Otherwise parameter 20 can be set to the number of filling cycles which have to occur before a tare measurement is taken again.