PD1

Tare average time

PD1


Command Group: Filling

Access:

Network interfaces:

RW

CANopen

MODbus

PD1 - Time over which the tare average will be build. Range: 0..65535.

PROFIbus


Synopsis:
CommandResponse
GetPD1P1:<Value>
SetPD1 <Value>OK (or ERR)
Valid forMin. valueMax. value
72.184 0 65535



PD1 Time during which the tare weight average is calculated. This function allows the correct tare value to be acquired although there may be a lot of vibrations on a (rotating) filling machine. Range: 0 … 65535 msec.