PD14

Fine-fill weight

PD14


Command Group: Filling

Access:

Network interfaces:

RW

CANopen

SDO2200sub0E

MODbus

231A,2

PD14 - Fine-fill weight. Part of the total filling weight done by the fine filling valve. Range: 0..99999.

PROFIbus

read 6,14 write 6,142


Synopsis:
CommandResponse
GetPD14P14:<Value>
SetPD14 <Value>OK (or ERR)
Valid forMin. valueMax. value
141.184 0 999999
142.184 0 999999
143.184 0 999999
151.184 0 999999
151.186 0 999999
64.184 0 999999
78.184 0 99999
88.184 0 262143



PD14 Fine-fill weight (in increments). This is the part of the total filling weight carried out by the fine filling valve.
The Coarse filling stop and fine filling begin when the actual weight reaches PD15 - PD14.