GG

Get gross weight

GG


Command Group: Weight

Access:

Network interfaces:

R

CANopen

SDO2900sub01

MODbus

2000,2

GG - Get the gross value

PROFIbus

read 14,0


Synopsis:
CommandResponse
GetGGG<Value>
Valid forMin. valueMax. value
141.181 0 999999
141.184 0 999999
141.185 0 999999
141.186 0 999999
142.181 0 999999
142.184 0 999999
142.185 0 999999
142.186 0 999999
143.181 0 999999
143.184 0 999999
143.185 0 999999
151.181 0 999999
151.184 0 999999
151.186 0 999999
162.181 0 999999
179.181 0 999999
64.181 0 999999
64.184 0 999999
68.181 0 99999
68.183 0 99999
69.181 0 999999
72.181 0 99999
72.184 0 99999
78.183 0 99999
78.184 0 99999
88.183 0 262143
88.184 0 262143
88.185 0 262143



GG Get the gross value - returns the current gross weight value. Issuing the GG command, which has no parameters, will return the gross weight value in the format G+01.100.
For multirange applications the format may be in the format G1+01.100, where the digit following the ‘G’ is in the range 1..3. See Output Format OF
For System80/MCS-64 and WCN122 this value is sent as a IEEE754 32 bit value with as many decimals as set by DP.
For all other devices the string has DP digits after the decimal point character.

See also MR, OF, DP, GN, GT. GS, GL. GW.