GD

Get Dosed

GD


Command Group: Filling

Access:

Network interfaces:

R

CANopen

SDO2900sub04

MODbus

2026,2

GD - Get the last filling net result

PROFIbus

read 11,0


Synopsis:
CommandResponse
GetGDD<Value>
Valid forMin. valueMax. value
141.184 0 262143
143.184 0 262143
64.184    
72.184    
78.184    
88.184 0 262143



GD Issuing the GD command, will return the last dosed weight value in the format D+01.100.

Using the LDM88 with a CANopen gateway (System80/MCS-64) a TPDO2 with the dosed weight is sent when the filling cycle ends. The weight value will be the dosed weight if everything is OK, or zero if the filling was aborted internally, e.g. Bag Rupture.

See also SC, AC, DI, DT, TR.
PD1, PD2, PD3, PD4, PD5, PD6, PD7, PD8, PD9, PD10, PD11, PD12, PD13, PD14, PD15, PD16, PD17, PD18, PD19, PD20, PD21.