DI

Dose Info

DI


Command Group: Filling

Access:

Network interfaces:

R

CANopen

SDO2400sub01

MODbus

206E,1

DI - Get the filling status

PROFIbus

read 5,0


Synopsis:
CommandResponse
GetDII:<Value>
Valid forMin. valueMax. value
141.184    
142.184    
143.184    
64.184    
72.184    
78.184    
88.184    



DI Issuing the DI command, will return via DOP software a result in the format I:000 (only low byte defined below).
The System80/MCS-64 has both bytes available thru the Gateway’s network (CANopen, PROFIbus or Modbus/Eth.).

This result can be decoded according to the table below:

Low byte filling statusHigh byte filling status (System80/MCS-64)
0 Idle
1Coarse valve open
2Fine valve open
4Dose program running
8Not used
16Not used
32Not used
64Tare out of range – no filling this cycle
128Zero out of range
0Idle
256Waiting for 2nd trigger
512Bottle on, calculating tare
768Pre-filling
1024Main Filling
1280Fine Filling
1536In-flight delay
1792Post fill calculations
2048Post Filling

See also SC, AC, DT, GD, TR.
PD1, PD2, PD3, PD4, PD5, PD6, PD7, PD8, PD9, PD10, PD11, PD12, PD13, PD14, PD15, PD16, PD17, PD18, PD19, PD20, PD21.